AC+True RMS
DCL1200R
Large diameter CT & DMM functions
Calibration available products
Calibration available products
- Lightweight approx. 290g
- Large LCD with backlight
- Easy to use large size data hold button
- Non-contact voltage detection function
- Auto V/Ω detection
- Max
1200A - True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- EF function
- Non-contact AC voltage detection
- Automatic Measurement for DCV/ACV/Ω
- Measurement function of DCV/ACV/Ωcan be automatically selected.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Backlight
- Allows indicator reading in a dark place.
Move your mouse pointer over or click on an icon to see a description of the icon.
Specifications
Function | Measuring range | Best accuracy | Resolution |
---|---|---|---|
ACA | 400/1200A | ±(1.7%+5) | 0.1A |
DCV | 6/60/600V | ±(0.7%+3) | 0.001V |
ACV | 6/60/600V | ±(1.7%+5) | 0.001V |
Auto resistance | 6k/60k/600k/6MΩ | ±(1.2%+4) | 1Ω |
Resistance | 600Ω | ±(2.2%+8) | 0.1Ω |
Frequency | 9.999/99.99/9.999k/30kHz | ±(0.6%+4) | 0.001Hz |
Capacitance | 100n/1000n/10μ/100μ/2000μF | ±(3.7%+5) | 0.1nF |
Continuity | Buzzer sounds at between 0Ω and 155Ω (±145Ω) Open voltage: approx. 0.4V | ||
Diode test | Open voltage: approx. 1.6V | ||
Voltage detection | Buzzer sounds and "-" is shown on LCD. Input sensitivity: approx. 20V or over (50/60Hz) |
Sampling rate | 5 times/sec. |
Bandwidth | ACA 50/60Hz ACV 50-500Hz |
Display | 6000 |
Clamp diameter/Conductor size | Φ42mm/20×54mm |
Battery | R03×2 |
Battery life | Approx. 90 hrs. at DCV (Alkaline battery/Backlight off) |
Size/Mass | H238×W95×D45mm/Approx. 290g |
Safety standards | IEC61010 CAT.Ⅲ 600V |