Clamp Meters
AC+True RMS
DCM660R
Suitable for electric work and air conditioning & DMM functions
Calibration available products
Calibration available products
- Inrush current measurement (within 100ms/above 10A)
- MAX/MIN value hold
- Frequency measurement by clamping and using test lead
- Max
660A - True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Inrush
- Inrush current can be measured.
- Auto power save
- The display disappears to bring the device into the power-save state when a certain time has passed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- MAX / MIN
- The maximum value and the minimum value are displayed or recorded. The recorded value can be seen later on the display.
- Backlight
- Allows indicator reading in a dark place.
Move your mouse pointer over or click on an icon to see a description of the icon.
Specifications
Function | Measuring range | Best accuracy | Resolution | Input impedance |
---|---|---|---|---|
ACA | 66/660A | ±(2%+5) | 0.01A | |
DCV | 600V | ±(1%+2) | 0.1V | 1MΩ |
ACV | 600V | ±(1.2%+5) | 0.1V | |
Frequency (A) | 660/6.6k/30k | ±(0.2%+1) | 0.1Hz | |
Frequency (V) | 660/6.6k/66k/100k | ±(0.2%+1) | 0.1Hz | |
Resistance | 660Ω | ±(1%+7) | 0.1Ω | |
Continuity | Buzzer sounds at less than 30Ω Open voltage: approx. 1.2V |
Sampling rate | 3 times/sec. |
Bandwidth | 50-500Hz |
Display | 6600 |
Clamp diameter/Conductor size | Φ30mm/10×50mm |
Battery | LR03×2 |
Battery life | Approx. 55 hrs.(Alkaline battery/Backlight off) |
Size/Mass | H208×W69×D38mm/Approx. 265g |
Safety standards | IEC61010 CAT.Ⅲ600V |