▲Page Top
search

	Sanwa Electric Instrument Co., Ltd.	Sanwa Electric Instrument Co., Ltd.

LCR Meters

Handheld Digital LCR meter


LCR701

LCR701
LCR701 LCR701

High-performance handheld LCR meter

  • Automatically selectable L/C/R measurement and Selectable Series/Parallel mode
  • Ls/Lp/Cs/Cp measurement with sub parameters (D/Q/θ/ESR)
  • 5 different measuring frequencies (100/120/1k/10k/100kHz)
  • OPEN/SHORT Calibration function
  • DC resistance function (7 ranges: 200.00Ω to 200.0MΩ)
  • Device Sorting mode to allow users to quickly sort passive devices such as L, C, and R
  • Optical link USB interface (optional)
  • Data hold, Backlight, Relative function
CE

Device Sorting function (PASS / FAIL result)

This meter can sort device values into PASS/FAIL at arbitrary threshold. LCR-USB, dedicated USB optical communication unit for LCR (separately available accessory), and the dedicated software allow you to record the test results in your PC.

Auto LCR mode

This meter can automatically select one of the following functions, resistance/capacitance/inductance measurement, even if the user doesn't recognize what a device is.

Specifications

Functions Ranges Best Accuracy
Ls/Lp 20.000µ/200.00µ/2000.0µ/20.000m/200.00m/2000.0m
20.000/200.00/2000.0/20.000kH
±(0.3%+3)
Cs/Cp 200.00p/2000.0p/20.00n/200.00n/2000.0n/
20.000µ/200.00µ/2000.0µ/20.00mF(50pF or less: out of accuracy)
±(0.3%+3)
Rs/Rp 20.000/200.00/2.0000k/20.000k/
200.00k/2.0000M/20.000M/200.0MΩ
±(0.3%+3)
Ω(DCR) 200.00/2.0000k/20.000k/200.00k/
2.0000M/20.000M/200.0MΩ
±(0.3%+3)
Sampling rate 1.2 times / second (LCR mode)
0.5 times / second (DCR mode)
Measuring frequencies 100/120/1k/10k/100kHz
Measuring mode Series / Parallel
Measurable parameters Ls / Lp / Cs / Cp / Rs / Rp / DCR (including D/Q/θ/ESR/RP)
Power supply 6LF22 (alkaline 9V)
6F22 (manganese 9V)
AC adapter AD-30-3 (optional)
Battery life 6LF22 (alkaline 9V): Approx. 40 hours
6F22 (manganese 9V): Approx. 18 hours
(auto LCR mode, 1 kHz)
Size / Mass H184×W87×D45 mm / Approx. 400g
Safety standards IEC61326-1, EN50581