Clamp Meters
AC+True RMS
DCM301
CAT.IV, AC current measurable max. 1000A
Calibration available products
Calibration available products
- The CT shape makes it easier to clamp cable in crowded.
- An electric field (EF) function is incorporated in the tip of the CT to enable detection of about AC 90V or more.
- Large, easy-to -press HOLD button.
- Equipped with LED light to illuminate the measurement target.
- Max
1000A - True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- EF function
- Non-contact AC voltage detection
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
- Backlight
- Allows indicator reading in a dark place.
- DC voltage
- Mark for clamp meters with DCV function.
Move your mouse pointer over or click on an icon to see a description of the icon.
Specifications
Function | Measuring range | Best accuracy | Resolution |
---|---|---|---|
ACA | 60.00/600.0/1000A | ±(2.5%+5) | 0.01A |
ACV | 6.000/60.00/600.0/1000V | ±(1.5%+3) | 0.001V |
DCV | 6.000/60.00/600.0/1000V | ±(1%+3) | 0.001V |
Resistance | 6.000k/60.00k/600.0k/6.000M/60.00MΩ | ±(2%+5) | 0.001kΩ |
Frequency | ACV 10Hz-10kHz, ACA 10Hz-2kHz | ±(1%+5) | 0.1Hz |
Capacitance | 60.00n/600.0n/6.000µ/60.00µ/600.0µ/6.000m/60.00mF | ±(4%+3) | 0.01nF |
Continuity | Buzzer sounds below 30Ω Open voltage: approx. 1V or less | ||
Detection of Electricity | Buzzer sounds, "-" is shown on LCD, and LED flickers
Detects ACV and EF of approx. 90V or more (50/60Hz) |
Sampling rate | Approx. 3 times/sec. |
Bandwidth | ACA 45-400Hz ACV 45Hz-1kHz |
Display | 6000/9999(Hz function) |
Clamp diameter/Conductor size | Φ34mm/10×64mm |
Battery | LR03×3 |
Battery life | Approx. 200 hrs. |
Size/Mass | H252×W85×D40mm/Approx. 360g |
Safety standards | IEC61010 CAT.Ⅳ600V/CAT.Ⅲ1000V |