Clamp Meters
DCM301AC+True RMS
CAT.IV, AC current measurable max. 1000A
- The CT shape makes it easier to clamp cable in crowded.
- An electric field (EF) function is incorporated in the tip of the CT to enable detection of about AC 90V or more.
- Large, easy-to -press HOLD button.
- Equipped with LED light to illuminate the measurement target.
- Max
1000A - True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- EF function
- Non-contact AC voltage detection
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
- Backlight
- Allows indicator reading in a dark place.
- DC voltage
- Mark for clamp meters with DCV function.
Move your mouse pointer over or click on an icon to see a description of the icon.
DLC470Leak current
Multifunctional leakage clamp meter
- Extract frequency range of mainly ACmA 50Hz/60Hz and ACA, with band-pass filter (BPF) function.
- MAX/MIN value hold
- Auto power off (30 min./Cancelable)
- Leakage current measurement Resolution 0.01mA
- Max
400A - Leakage current
- A clamp meter that can make the measurement of leakage current have a range to allow measurements in milliamp.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- BandPass Filter
- Pass through a particular frequency and will reduce other bandwidth.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- MAX / MIN
- The maximum value and the minimum value are displayed or recorded. The recorded value can be seen later on the display.
- Backlight
- Allows indicator reading in a dark place.
Move your mouse pointer over or click on an icon to see a description of the icon.
DCM400AC
Low cost & DMM functions
- 4000 counts, 42 segments analog bar graph
- Frequency measurement by clamping and using test lead
- Auto power off (30 min.)
- Low battery power indication
- Max
400A - Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
Move your mouse pointer over or click on an icon to see a description of the icon.
DCL1000AC
Large diameter CT, AC current measurable max. 1000A
- Lightweight approx. 290g
- Large LCD
- Easy to use large size data hold button
- Max
1000A - Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
Move your mouse pointer over or click on an icon to see a description of the icon.
DCM400ADDC/AC
Suitable for automotive maintenance & DMM functions
- 4000 counts, 42 segments analog bar graph
- Auto power off (30 min.)
- Low battery power indication
- Max
400A - DC / AC measurable
- Both ACA and DCA are measurable.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
Move your mouse pointer over or click on an icon to see a description of the icon.
DCL11RAC+True RMS
RMS mini clamp meter with backlight
- Compact pocket size
- Auto power off (15 min./Cancelable)
- Max
300A - True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Backlight
- Allows indicator reading in a dark place.
Move your mouse pointer over or click on an icon to see a description of the icon.
DCM60RAC+True RMS
Low cost & DMM functions
- ACV & resistance measurement
- Small design & easy to carry
- Max
600A - True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
Move your mouse pointer over or click on an icon to see a description of the icon.
DCM660RAC+True RMS
Suitable for electric work and air conditioning & DMM functions
- Inrush current measurement (within 100ms/above 10A)
- MAX/MIN value hold
- Frequency measurement by clamping and using test lead
- Max
660A - True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Inrush
- Inrush current can be measured.
- Auto power save
- The display disappears to bring the device into the power-save state when a certain time has passed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- MAX / MIN
- The maximum value and the minimum value are displayed or recorded. The recorded value can be seen later on the display.
- Backlight
- Allows indicator reading in a dark place.
Move your mouse pointer over or click on an icon to see a description of the icon.
DCL1200RAC+True RMS
Large diameter CT & DMM functions
- Lightweight approx. 290g
- Large LCD with backlight
- Easy to use large size data hold button
- Non-contact voltage detection function
- Auto V/Ω detection
- Max
1200A - True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- EF function
- Non-contact AC voltage detection
- Automatic Measurement for DCV/ACV/Ω
- Measurement function of DCV/ACV/Ωcan be automatically selected.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Backlight
- Allows indicator reading in a dark place.
Move your mouse pointer over or click on an icon to see a description of the icon.
DCL3000RAC+True RMS
ACA clamp meter with flexible CT
- Flexibility facilitating conductor clamping even in narrow space
- MAX/MIN value hold
- Air-core coil for weight reduction
- Auto power off (15 min./Cancelable)
- Max
3000A - True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- MAX / MIN
- The maximum value and the minimum value are displayed or recorded. The recorded value can be seen later on the display.
- Backlight
- Allows indicator reading in a dark place.
Move your mouse pointer over or click on an icon to see a description of the icon.
DCL31DRDC/AC+True RMS
DC/AC RMS mini clamp meter with peak hold function
- Compact pocket size
- Auto power off (15min./Cancelable)
- Max
400A - True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- DC / AC measurable
- Both ACA and DCA are measurable.
- peak hold
- The peak value like in-rush current is indicated. The minimum pulse width capturable differs according to models.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Backlight
- Allows indicator reading in a dark place.
Move your mouse pointer over or click on an icon to see a description of the icon.
DCM600DRDC/AC+True RMS
Suitable for maintenance of vehicle, hybrid vehicle, EV & DMM functions
- AC/DC current measurable max. 600A
- Peak hold (Interval: 1ms)
- Auto power save (30min./Cancelable)
- Max
600A - True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- DC / AC measurable
- Both ACA and DCA are measurable.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- peak hold
- The peak value like in-rush current is indicated. The minimum pulse width capturable differs according to models.
- Auto power save
- The display disappears to bring the device into the power-save state when a certain time has passed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
- Backlight
- Allows indicator reading in a dark place.
Move your mouse pointer over or click on an icon to see a description of the icon.
DCM2000DRDC/AC+True RMS
DC/AC current measurable max. 2000A, CAT.IV 1000V
- Dual display shows voltage/current and its frequency
- EF (Electric Field) detection
- VFD (Variable Frequency Drive) frequency measurement
- Low input impedance voltage measurement capable of attenuating the effects of ghost voltages
- Peak hold (Interval: 5 ms)
- Auto power save (30 min./Cancelable)
- Max
2000A - True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- DC / AC measurable
- Both ACA and DCA are measurable.
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- EF function
- Non-contact AC voltage detection
- peak hold
- The peak value like in-rush current is indicated. The minimum pulse width capturable differs according to models.
- Low-pass filter
- Low-pass filter cuts current value of high frequency.
- Automatic Measurement for DCV/ACV/Ω
- Measurement function of DCV/ACV/Ωcan be automatically selected.
- Auto power save
- The display disappears to bring the device into the power-save state when a certain time has passed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
- Backlight
- Allows indicator reading in a dark place.