Digital Multimeters
PC7000High accuracy & high resolution (PC Link)
500000 counts for DCV, Dual display
- 50000 & 500000 counts
(Selectable 5-4 / 5 digits 500000 counts for DCV) - Dual display shows voltage/current and its frequency, and AC components and DC components of voltage/current
- Low-pass filter for variable frequency drive(VFD) circuit
- Capture (peak hold), Interval: 0.8ms
- MAX/MIN/AVG recording mode
- K type thermocouple temperature measurement -50℃ ~ 1000℃
- Conductance measurement
- Auto power save (17min.)(cancelable)
- True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- Dual Display
- Allows simultaneous reading.
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Duty cycle
- The duty cycle of repeating waveform is indicated on a percentage basis (%). It can be used for the analysis of control signals.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Temperature measurement
- Temperature can be measured using a probe.
- 4-20mA%
- 4-20mA for sending instrumentation signals. Expresses the current loop of 4mA as 0% and 20mA as 100%
- dBm
- Scaling of voltage values is performed according to the reference impedance into dBm. Convenient for use with audio equipment.
- peak hold
- The peak value like in-rush current is indicated. The minimum pulse width capturable differs according to models.
- Low-pass filter
- Low-pass filter cuts current value of high frequency.
- Auto power save
- The display disappears to bring the device into the power-save state when a certain time has passed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
- MAX / MIN / AVG
- The maximum value, the minimum value and the average value are displayed or recorded. The recorded value can be seen later on the display.
- Backlight
- Allows indicator reading in a dark place.
- USB conneciton
- Data can be output by connecting to the USB port of a PC.
- Temperature measurement with PC Link
- Temperature can be measured using the optional probe and PC Link software. (T-300PC is necessary.)
Move your mouse pointer over or click on an icon to see a description of the icon.
PC710Peak hold function, temperature probe included
True RMS, Dual display
- 6000&9999 counts
- Dual display shows voltage/current and its frequency, and AC components and DC components of voltage/current
- EF(Electric Field)detection to indicate signal strength of electric field which surrounds current carrying conductors
- Capture (peak hold), Interval:1ms
- MAX/MIN/AVG recording mode
- K type thermocouple temperature measurement -50℃ ~ 1000℃
- Conductance measurement
- Auto power save (17min.) (cancelable)
- True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- Dual Display
- Allows simultaneous reading.
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Duty cycle
- The duty cycle of repeating waveform is indicated on a percentage basis (%). It can be used for the analysis of control signals.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Temperature measurement
- Temperature can be measured using a probe.
- EF function
- Non-contact AC voltage detection
- peak hold
- The peak value like in-rush current is indicated. The minimum pulse width capturable differs according to models.
- Auto power save
- The display disappears to bring the device into the power-save state when a certain time has passed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
- MAX / MIN / AVG
- The maximum value, the minimum value and the average value are displayed or recorded. The recorded value can be seen later on the display.
- Backlight
- Allows indicator reading in a dark place.
- USB conneciton
- Data can be output by connecting to the USB port of a PC.
- Temperature measurement with PC Link
- Temperature can be measured using the optional probe and PC Link software. (T-300PC is necessary.)
Move your mouse pointer over or click on an icon to see a description of the icon.
PC720MHigh accuracy & built-in memory (PC Link)
87,382 points data logging in built-in memory
- 6000&9999 counts
- Dual display with blacklight
- High speed bar graph
- K type thermocouple temperature measurement -50℃ ~ 1000℃
- Conductance measurement
- MAX/MIN recoding mode
- Caputure (peak hold), Interval: 1ms
- Auto power save (30min.)(cancelable)
- True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- Dual Display
- Allows simultaneous reading.
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Duty cycle
- The duty cycle of repeating waveform is indicated on a percentage basis (%). It can be used for the analysis of control signals.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Temperature measurement
- Temperature can be measured using a probe.
- peak hold
- The peak value like in-rush current is indicated. The minimum pulse width capturable differs according to models.
- Automatic Measurement for DCV/ACV/Ω
- Measurement function of DCV/ACV/Ωcan be automatically selected.
- Logging
- The reading can be stored in the meter itself.
- Auto power save
- The display disappears to bring the device into the power-save state when a certain time has passed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
- MAX / MIN
- The maximum value and the minimum value are displayed or recorded. The recorded value can be seen later on the display.
- Backlight
- Allows indicator reading in a dark place.
- USB conneciton
- Data can be output by connecting to the USB port of a PC.
- Temperature measurement with PC Link
- Temperature can be measured using the optional probe and PC Link software. (T-300PC is necessary.)
Move your mouse pointer over or click on an icon to see a description of the icon.
PC700High accuracy (PC Link)
Dual display, Best accuracy 0.06%
- 6000&9999 counts
- DC/AC voltage measurement resolution 0.01mV
- Dual display shows voltage/current and its frequency, and AD components and DC components of voltage/current
- High speed bar graph
- Auto power save (30min.)(cancelable)
- Dual Display
- Allows simultaneous reading.
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Duty cycle
- The duty cycle of repeating waveform is indicated on a percentage basis (%). It can be used for the analysis of control signals.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Auto power save
- The display disappears to bring the device into the power-save state when a certain time has passed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
- USB conneciton
- Data can be output by connecting to the USB port of a PC.
- Temperature measurement with PC Link
- Temperature can be measured using the optional probe and PC Link software. (T-300PC is necessary.)
Move your mouse pointer over or click on an icon to see a description of the icon.
PC773Data processing (PC connectable)
11000 counts, Minimum resolusion 0.01mV,0.01Ω
- 11000 counts
- Best accuracy 0.28%
- Double molding of elastic elastomer materials
- AC/DC current measurable max.11A
- Continuity buzzer and LED lamp
- Auto power save(30min.)(cancelable)
- True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Continuity check
- The LED lights up when the measuring object is electrically conducting.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
- Backlight
- Allows indicator reading in a dark place.
- USB conneciton
- Data can be output by connecting to the USB port of a PC.
- Temperature measurement with PC Link
- Temperature can be measured using the optional probe and PC Link software. (T-300PC is necessary.)
Move your mouse pointer over or click on an icon to see a description of the icon.
PC20Data processing (PC Link)
AC adapter connectable for long haul measurement
- 4000 counts
- 0.5% best accuracy
- Safety cover for 4・10A terminal
- Safety cap for AC adapter terminal
- Protective holster with wall hanger and lead holder
- Tilt stand
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Low power ohm
- Resistance is measured by applying voltage of approximately 0.4V or less on a measuring object. It is characterized by the fact that the semiconductor does not conduct at approximately 0.4V or less even in forward direction.
- USB conneciton
- Data can be output by connecting to the USB port of a PC.
- Temperature measurement with PC Link
- Temperature can be measured using the optional probe and PC Link software. (T-300PC is necessary.)
Move your mouse pointer over or click on an icon to see a description of the icon.
CD770New standard
Capacitance and frequency can be measured too
- 4000 counts
- Easy to read large LCD
- Thermo plastic elstomer, high resistance against drop shock
- Safety cap on current terminal
- Auto power off (30min.)(cancelable)
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
- Low power ohm
- Resistance is measured by applying voltage of approximately 0.4V or less on a measuring object. It is characterized by the fact that the semiconductor does not conduct at approximately 0.4V or less even in forward direction.
Move your mouse pointer over or click on an icon to see a description of the icon.
CD771Multifunctional new standard
Backlight & Cont.buzzer with LED
- 4000 counts
- Easy to read large LCD with backlight
- Large breaking capacity fuse 30kA
- 1.5V battery check function
- Thermo plastic elstomer, high resistance against drop shock
- Safety cap on current terminal
- Auto power off(30min.)(cancelable)
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Continuity check
- The LED lights up when the measuring object is electrically conducting.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Battery check
- Battery voltage is measured and assessed by running a given current.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
- Low power ohm
- Resistance is measured by applying voltage of approximately 0.4V or less on a measuring object. It is characterized by the fact that the semiconductor does not conduct at approximately 0.4V or less even in forward direction.
- Backlight
- Allows indicator reading in a dark place.
Move your mouse pointer over or click on an icon to see a description of the icon.
CD772Ture RMS new standard
Blacklight & Temperature measurement
- 4000 counts
- Easy to read large LCD with backlight
- Large breaking capacity fuse 30kA
- K type thermocouple temperature measurement -20℃ ~ 300℃
- Thermo plastic elstomer, high resistance against drop shock
- Safety cap on current terminal
- Auto power off (30min.)(cancelable)
- True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Continuity check
- The LED lights up when the measuring object is electrically conducting.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Temperature measurement
- Temperature can be measured using a probe.
- Auto power save
- The display disappears to bring the device into the power-save state when a certain time has passed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
- Low power ohm
- Resistance is measured by applying voltage of approximately 0.4V or less on a measuring object. It is characterized by the fact that the semiconductor does not conduct at approximately 0.4V or less even in forward direction.
- Backlight
- Allows indicator reading in a dark place.
Move your mouse pointer over or click on an icon to see a description of the icon.
RD700Multifunction
High input impedance 1000MΩ
- 4000 counts
- Best accuracy0.3%
- K type thermocouple temperature measurement -20℃ - 300℃
- Frequency measurement
※Input voltage:20VACrms and uder
※Input signal:sign wave or square wave with 40% - 70%duty
※Input sensivity:10Hz-20kHz/0.9Vrms and above
:20kHz-500kHz/2.6Vp or 1.9Vrms and above
:500kHz~1MHz/4.2Vp or 3Vrms and above - Max value hold
- Auto power off (30min,)(cancelable)
- Alarm for importer test lead insertion to current terminal
- Protective holster with wall hanger and lead holder
- Tilt stand
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Temperature measurement
- Temperature can be measured using a probe.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
- MAX
- The maximum value is displayed or recorded. The recorded value can be seen later on the display.
- Low power ohm
- Resistance is measured by applying voltage of approximately 0.4V or less on a measuring object. It is characterized by the fact that the semiconductor does not conduct at approximately 0.4V or less even in forward direction.
Move your mouse pointer over or click on an icon to see a description of the icon.
RD701Multifunction
High input impedance 1000MΩ
- 4000 counts
- Best accuracy 0.3%
- K type thermocouple temperature measurement -20℃ - 300℃
- Frequency measurement
※Input voltage:20VACrms and under
※Input signal:sing wave or square wave with 40%-70% duty
※Input sensitivity:10Hz~20kHz/0.9Vrms and above
:20kHz~500kHz/2.6Vp or 1.9Vrms and above
:500kHz~1MHz/4.2Vp or 3Vrms and above - Max value hold
- Auto power off (30min.)(cancelable)
- Alarm for importer test lead insertion to current terminal
- Protective holster with wall hanger and lead holder
- Tilt stand
- True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Temperature measurement
- Temperature can be measured using a probe.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
- MAX
- The maximum value is displayed or recorded. The recorded value can be seen later on the display.
- Low power ohm
- Resistance is measured by applying voltage of approximately 0.4V or less on a measuring object. It is characterized by the fact that the semiconductor does not conduct at approximately 0.4V or less even in forward direction.
Move your mouse pointer over or click on an icon to see a description of the icon.
CD732Multifunction
High-speed bar graph & Cont.buzzer with LED
- 6000 counts
- Using fire-retardand materials for main unit case and circuit board
- Wide-range capacitance measurement
(0.01nF to 3999μF) - Safety cover for 6・15A terminal
- Protective holster with wall hanger and lead holster
- Auto power save (16mn.) (cancelable)
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Duty cycle
- The duty cycle of repeating waveform is indicated on a percentage basis (%). It can be used for the analysis of control signals.
- Continuity check
- The LED lights up when the measuring object is electrically conducting.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Auto power save
- The display disappears to bring the device into the power-save state when a certain time has passed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
Move your mouse pointer over or click on an icon to see a description of the icon.
CD800aALL-IN-ONE DMM
Tough body cover
- 4000 counts
- Best accuracy 0.7%
- Auto power off(30min.)(cancelable)
- Low power ohm(input voltage 0.4V)at continuity range
- Solid & portective body cover that can also be used as a tilt stand
- Chip resister holder behind the body cover
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Duty cycle
- The duty cycle of repeating waveform is indicated on a percentage basis (%). It can be used for the analysis of control signals.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
- Low power ohm
- Resistance is measured by applying voltage of approximately 0.4V or less on a measuring object. It is characterized by the fact that the semiconductor does not conduct at approximately 0.4V or less even in forward direction.
Move your mouse pointer over or click on an icon to see a description of the icon.
PM3Pocket type
8.5mm thick body with multi-function
- 4000 counts
- Best accuracy 0.7%
- Auto power off(15min.)(cancelable)
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Duty cycle
- The duty cycle of repeating waveform is indicated on a percentage basis (%). It can be used for the analysis of control signals.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
- Low power ohm
- Resistance is measured by applying voltage of approximately 0.4V or less on a measuring object. It is characterized by the fact that the semiconductor does not conduct at approximately 0.4V or less even in forward direction.
Move your mouse pointer over or click on an icon to see a description of the icon.
PM7aPocket type
Pocket size DMM with integrated protective case
- 4000 counts
- Best accuracy 0.7%
- Auto power off(15min.)
- Low power ohm (input voltage 0.4V) at continuity range
- Power saving design
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Low power ohm
- Resistance is measured by applying voltage of approximately 0.4V or less on a measuring object. It is characterized by the fact that the semiconductor does not conduct at approximately 0.4V or less even in forward direction.
Move your mouse pointer over or click on an icon to see a description of the icon.
PM11Pocket type
Test leads fixing feature to enable one-hand measurement
- 4000 counts
- Best accuracy 0.8%
- Analog bar graph
- Test leads storable in the main unit
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
Move your mouse pointer over or click on an icon to see a description of the icon.
PS8aPocket type
Solar charge battery DMM
- 4000 counts
- Best accuracy 0.7%
- Auto power off(15min.)
- Low power ohm(input voltage 0.4V)at continuity range
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Low power ohm
- Resistance is measured by applying voltage of approximately 0.4V or less on a measuring object. It is characterized by the fact that the semiconductor does not conduct at approximately 0.4V or less even in forward direction.
Move your mouse pointer over or click on an icon to see a description of the icon.
KP1Volt Tester
CAT.IV Volt tester
- Self test-checking failures of LCD, disconnection of a lead wire
- EF(Electric Field)detection
- LCD with backlight & LED Light for dark place
- Auto data hold
- Auto power off(1min.)
- Auto identification of AC or DC voltage
- True RMS (True root-mean-square value)
- True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- EF function
- Non-contact AC voltage detection
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Backlight
- Allows indicator reading in a dark place.
Move your mouse pointer over or click on an icon to see a description of the icon.
PM33aHybrid Digital Multimeters
Hybrid pocket size DMM + clamp meter
- Lightweight approx.160g
- MAX/MIN value hold
- U-shaped clamp sensor, 7mm thick
- DC/AC current measurable up to 100A
- Auto power off(30min.)
- Max
100A - DC / AC measurable
- Both ACA and DCA are measurable.
- Frequency
- Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
- Capacitor
- Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
- Duty cycle
- The duty cycle of repeating waveform is indicated on a percentage basis (%). It can be used for the analysis of control signals.
- Continuity buzzer
- The buzzer sounds when the measuring object is electrically conducting.
- Auto power off
- Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
- Data hold
- A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
- Range hold
- The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
- Measurement of relative value
- A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
- MAX / MIN
- The maximum value and the minimum value are displayed or recorded. The recorded value can be seen later on the display.
Move your mouse pointer over or click on an icon to see a description of the icon.